Calcite Filter Media
WATER TREATMENT • CALCIUM CARBONATE MEDIA

Calcite Filter Media

Natural calcium carbonate granules used in suitable water-treatment systems to help neutralise acidic water and raise pH. RMM Calcite Filter Media is intended for filter-vessel applications where controlled mineral dissolution can help reduce the corrosive nature of low-pH water.

Natural calcium carbonateGranular filter mediaWater-treatment use
RMM Calcite Filter Media bag and calcite granules
MaterialNatural Calcium Carbonate
Product FormGranular media
ApplicationAcidic water pH correction
UseFilter vessel media bed
WHAT IS CALCITE MEDIA?

A Natural Mineral for Acidic Water Neutralisation

Calcite is a naturally occurring form of calcium carbonate (CaCO₃). When acidic water passes through a bed of calcite granules, a portion of the media dissolves and reacts with the acidity in the water. This process can increase pH and add calcium and alkalinity to the treated water.

Calcite is commonly selected for low-pH water where the treatment objective is to reduce corrosive conditions in plumbing and water-distribution systems. Its performance depends on the incoming water chemistry, contact time, flow rate and filter design.

✓pH correction: helps raise the pH of suitable acidic water through gradual dissolution.
✓Corrosion control: can help reduce the corrosive tendency of low-pH water in compatible systems.
✓Mineral addition: dissolution adds calcium and bicarbonate alkalinity to the water.
✓Media replenishment: the calcite bed can be topped up as the granules are gradually consumed.
HOW IT WORKS
Acidic water
+ Calcite
→ Balanced pH

As water flows through the calcite bed, calcium carbonate dissolves in response to the water chemistry. The amount dissolved is influenced by pH, alkalinity, contact time and operating conditions.

Calcium carbonateGradual dissolutionpH adjustment
KEY FUNCTIONS

Why Use Calcite Filter Media?

Calcite is used as a neutralising media in water-treatment systems. It does not replace a complete filtration or disinfection process; it is selected for its role in correcting acidic water chemistry.

01 / pH ADJUSTMENT

Raises Water pH

Gradual dissolution of calcium carbonate helps neutralise acidity and move low-pH water towards a less corrosive condition.

02 / PLUMBING PROTECTION

Helps Reduce Corrosion

By correcting acidic water conditions, calcite can help reduce corrosion potential in compatible pipes, fittings and water systems.

03 / MINERAL BALANCE

Adds Calcium & Alkalinity

As calcite dissolves, it contributes calcium and bicarbonate alkalinity. This can also increase water hardness.

04 / OPERATION

Simple Media Bed

Calcite is commonly loaded into a suitable filter vessel and replenished as the media is consumed during operation.

05 / NATURAL MINERAL

Mineral-Based Treatment

Uses naturally occurring calcium carbonate as the neutralising medium rather than relying only on continuous liquid chemical dosing.

06 / SYSTEM DESIGN

Application-Based Selection

Media grade and filter design should be matched to pH, alkalinity, flow rate, contact time and water-quality objectives.

APPLICATION AREAS

Where Is Calcite Filter Media Used?

Calcite is used in suitable water-treatment systems where acidic water requires pH correction. The treatment design should be based on a water analysis and the intended end use.

01

Borewell & Well Water

For suitable groundwater sources where low pH and corrosive water conditions have been identified through testing.

02

RO Permeate Re-Mineralisation

Can be used in selected post-RO systems to increase pH and add calcium, subject to the required treated-water specification.

03

Residential & Commercial Water Systems

For appropriately designed point-of-entry or central water-treatment systems requiring acidic water neutralisation.

04

Industrial Water Treatment

For industrial water lines and process-water systems where pH correction and reduced corrosivity are required.

FILTER OPERATION

How Does a Calcite Filter Work?

Calcite is normally used as a granular bed inside a properly designed filter vessel. Operating conditions should be selected by the water-treatment system designer.

STEP 01

Test the Water

Check pH, alkalinity, hardness and flow requirements before selecting the neutralising media and vessel.

STEP 02

Load the Filter Vessel

Fill the vessel with the selected calcite grade over a suitable support and underdrain arrangement.

STEP 03

Pass Water Through the Bed

Water contacts the calcite granules; a portion dissolves and reacts with acidity as the water flows through.

STEP 04

Backwash & Refill

Backwash as required by the system design and replenish media as its bed level decreases through consumption.

Operating frequency, backwash rate, vessel dimensions and media consumption depend on the water chemistry and system design. Follow the equipment designer's operating instructions.

PRODUCT INFORMATION

Calcite Filter Media – Product Parameters

RMM has discussed a 16/40 grade for calcite media, with specific gravity around 2.7 and Mohs hardness around 3.0. Confirm the final values and current availability against the product COA/TDS before purchase.

ParameterIndicative Product Information
MaterialNatural Calcium Carbonate (Calcite)
Product FormGranular filter media
Grade / Size16/40 (as previously discussed; confirm availability)
Specific GravityApproximately 2.7 (to be confirmed by COA/TDS)
Mohs HardnessApproximately 3.0 (typical calcite value)
AppearanceWhite to off-white; confirm actual supplied lot
PackagingConfirm available pack size with RMM

Important: Particle-size distribution, CaCO₃ content, moisture, insoluble matter, bulk density and packaging should be specified and confirmed for each order. Values shown as approximate are not a substitute for a batch-specific Certificate of Analysis.

SELECT THE RIGHT GRADE

What Should You Check Before Buying Calcite Media?

The correct calcite grade depends on the incoming water and the filter's operating conditions. Before placing an order, share the following information with your water-treatment supplier or system designer.

✓Raw water pH and alkalinity
✓Required service flow rate and daily water volume
✓Required particle-size range and filter-vessel design
✓Target treated-water pH and acceptable hardness
✓Backwash arrangement and media replenishment plan
A NOTE ON WATER QUALITY
Test first.
Design right.

Calcite raises pH by dissolving calcium carbonate; it can also increase hardness. It is not a universal contaminant-removal media and does not by itself disinfect water or remove dissolved salts, metals or suspended solids.

Water analysisFlow rateContact time
FREQUENTLY ASKED QUESTIONS

Calcite Filter Media

What is Calcite Filter Media?

Calcite filter media is a granular form of natural calcium carbonate used in suitable water-treatment systems to neutralise acidic water and raise pH through gradual dissolution.

How does calcite increase water pH?

When acidic water passes through a calcite bed, some calcium carbonate dissolves and reacts with acidity. The amount dissolved depends on the water chemistry and operating conditions.

Does calcite media increase water hardness?

Yes. As calcium carbonate dissolves, it adds calcium to the water and can increase hardness. The treated-water quality should be checked to determine whether additional treatment is needed.

Can calcite be used with RO water?

Calcite may be used in selected post-RO remineralisation or pH-correction systems. The grade, contact time and vessel design should be selected based on the permeate quality and target water specification.

Does calcite remove iron, bacteria or dissolved salts?

Calcite is primarily a pH-neutralising medium. It should not be represented as a standalone solution for iron removal, disinfection or dissolved-salt removal. Separate treatment stages may be required.

How often should calcite media be replenished?

Calcite is gradually consumed during operation. Replenishment frequency depends on incoming water acidity, flow, operating hours and system design. Inspect the media bed and follow the equipment supplier's maintenance schedule.

Which particle size should I choose?

Particle size should be selected according to the filter vessel, service flow, contact time and backwash design. Share your system details with RMM to discuss the available grade.

Can RMM provide technical details?

Contact RMM with your required particle size, quantity and application. Request the current TDS and COA to verify the technical parameters of the offered grade.